Skip to content

How To Install Sharkbite Fittings On Existing Copper Pipe – In Detail

Turn off the water at the shutoff valve, cut the pipe, deburr the cut end, clean the pipe with a copper pipe cleaning solution, insert the SharkBite push-fit fitting into the pipe, and turn on the water at the shutoff valve.

  • Cut the copper pipe cleanly and squarely using a pipe cutter. Deburr the inside and outside of the pipe with a pipe reamer.
  • Clean the end of the pipe with a clean rag.
  • Slide the SharkBite fitting onto the pipe. Make sure it’s fully seated.
  • Use a pipe wrench to tighten the collar until it’s snug.

That’s it! SharkBite fittings are designed for use with copper, PEX, CPVC, and PE-RT pipe and can be installed in wet or dry conditions.

How To Install Sharkbite Fittings On Existing Copper Pipe

How Do You Properly Clean The Copper Pipe Before Installing The SharkBite Fitting?

Before installing a SharkBite fitting on a copper pipe, the pipe must be cleaned with a wire brush to remove any oxidation.
If you’re working with copper pipe, you’ll want to clean the pipe before you install your SharkBite fitting. Here’s a step-by-step guide on how to do it:

  1. Start by turning off the water supply to the area where you’ll be working.
  2. Next, use a pipe wrench to loosen the fitting that’s currently attached to the copper pipe.
  3. Once the fitting is loose, you can remove it from the pipe.
  4. Now it’s time to clean the copper pipe. You can do this by using a wire brush to remove any debris or corrosion that’s on the pipe.
  5. Once the pipe is clean, you can reattach the fitting.
  6. Finally, turn the water supply back on and test the fitting to make sure it’s secure.

What Is The Maximum Operating Temperature For SharkBite Fittings?

SharkBite fittings have a maximum operating temperature of 200 degrees Fahrenheit.
SharkBite is a brand of push-to-connect plumbing fittings, valves, and piping used in residential and commercial plumbing applications. The company’s products are manufactured in the United States and are certified to meet several international standards, including ANSI/NSF 61 and ASTM F2159.

SharkBite fittings are made of brass and are designed to be used with copper, PEX, CPVC, and PE-RT pipe and tubing. The fittings can be installed without the use of tools, and they are compatible with both SharkBite and non-SharkBite products. The maximum operating temperature for SharkBite fittings is 200 degrees Fahrenheit. This means that the fittings can be used in applications where the water temperature will not exceed 200 degrees Fahrenheit.

One example of an application where the maximum operating temperature for SharkBite fittings would be applicable is in a domestic hot water system. In this type of system, the water is typically heated to between 130 and 140 degrees Fahrenheit. This water is then circulated through the home’s plumbing system and is used for tasks such as bathing, cooking, and cleaning.

SharkBite fittings are also commonly used in radiant heating systems. In these systems, water is heated to a temperature of between 130 and 180 degrees Fahrenheit and is circulated through a series of pipes. The heat from the water warms the floor, walls, and other surfaces in the home.

The maximum operating temperature for SharkBite fittings is also relevant in commercial applications. For example, the fittings can be used in restaurants where dishwashing machines are used. These machines typically operate at temperatures between 140 and 180 degrees Fahrenheit.

In conclusion, the maximum operating temperature for SharkBite fittings is 200 degrees Fahrenheit. This temperature rating means that the fittings can be used in a variety of applications, including domestic hot water systems, radiant heating systems, and commercial dishwashing machines.

What Is The Maximum Operating Pressure For SharkBite Fittings?

What Is The Maximum Operating Pressure For SharkBite Fittings

The maximum operating pressure for SharkBite fittings is 200 PSI.
SharkBite fittings are pressure-rated according to the maximum operating pressure of the pipe they are being used with. The maximum operating pressure for SharkBite fittings is 200 psi. For example, if you are using SharkBite fittings with a 1/2pipe, the maximum operating pressure for the fittings would be 200 psi.

What Are The Recommended Torque Values For SharkBite Fittings?

What Are The Recommended Torque Values For SharkBite Fittings

There are no recommended torque values for SharkBite fittings.
If you’re working with SharkBite fittings, it’s important to know the recommended torque values. This will ensure that you get a tight seal and avoid any leaks. The recommended torque values for SharkBite fittings are as follows:

  • For 1/2fittings, use a 5/16hex key and tighten to 15 ft-lbs
  • For 3/4fittings, use a 3/8hex key and tighten to 30 ft-lbs
  • For 1fittings, use a 1/2hex key and tighten to 60 ft-lbs
  • For 1-1/4fittings, use a 9/16hex key and tighten to 85 ft-lbs
  • For 1-1/2fittings, use a 5/8hex key and tighten to 120 ft-lbs
  • For 2fittings, use a 3/4hex key and tighten to 160 ft-lbs

Now that you know the recommended torque values for SharkBite fittings, let’s look at an example. Let’s say you’re using a 1/2SharkBite fitting. In this case, you would use a 5/16hex key and tighten to 15 ft-lbs. This will ensure a tight seal and avoid any leaks.

FAQ:

1.What Are The Recommended Tooling For SharkBite Fittings Installation?

Ans: There are three primary recommended tooling for SharkBite fittings installation: a cutter, a deburring tool, and a depth gauge. The cutter is used to cleanly cut the pipe, and the deburring tool is used to remove any sharp edges or burrs that may be present. The depth gauge is used to ensure that the SharkBite fitting is installed at the proper depth.

2.What Are The Hazards Associated With SharkBite Fittings?

Ans: SharkBite fittings are a type of quick-connect fitting that is commonly used in plumbing applications. While these fittings are convenient and easy to use, there are some potential hazards that should be considered. One hazard is that the fitting can come loose, which can cause a leak. Another hazard is that the fitting can become clogged, which can cause a buildup of pressure and potentially cause a burst pipe.

3.What Are The Precautions That Should Be Taken When Working With SharkBite Fittings?

Ans: The manufacturer of SharkBite recommends the following safety precautions when working with their fittings:
#Wear gloves when handling the fittings
#Do not use SharkBite fittings with compressed air or gas
#Use SharkBite fittings only with copper, CPVC, or PEX pipe
#Do not reuse SharkBite fittings
#Turn off the water before installing or removing SharkBite fittings
#Do not use SharkBite fittings on main water lines

4.What Are The Troubleshooting Tips For SharkBite Fittings?

Ans: If you are having trouble with SharkBite fittings, here are some troubleshooting tips:

*Make sure that the pipe you are using is the correct size for the fitting.
*Check that the O-ring is properly seated in the fitting.
*Ensure that the pipe is properly inserted into the fitting.
*Make sure that the fitting is not damaged.
*If you are still having trouble, contact SharkBite customer service for assistance.

Conclusion

If you’re still unclear on how to install Sharkbite fittings on existing copper pipe, please leave a comment below and we’ll be happy to help.

Leave a Reply

Your email address will not be published. Required fields are marked *